Suncenter Brand Model: Dggd10 10: 1 Ratio Air Driven High Pressure Liquid Pump for Pressure Gauge Testing

Suncenter Brand Model: Dggd10 10: 1 Ratio Air Driven High Pressure Liquid Pump for Pressure Gauge Testing

CZPT brand Product:DGGD10  10:1 ratio air pushed higher stress liquid pump for strain gauge screening
We offer the most full selection of Air driven liquid pump models in the business calculated for:

  1. Capacity of supreme force, stream or output horsepower.
  2. Compatibility with a wide selection of liquids, such as oil, drinking water and chemical apps.

CZPT pumps are air driven at a push air pressure of 1bar to 8bar (fourteen.5 psi to116 psi) by the regular CZPT. Generally the principle of procedure is related to a reciprocating amplifier the place management of the piston at the finish place is controlled by a pilot operated four/2 way valve.

CZPT pumps characteristic a huge air piston joint to a smaller diameter plunger. The force ratio is the variation of these two regions and is the technique of determining highest outlet stress. Increased pressures received by making use of increased stress ratios.CZPT product figures reflect the pumps nominal force ratios, whilst the specialized info implies exact ratios. The outlet pressure is effortlessly to set by means of a simple air regulator. By multiplying the strain ratio by the available store air strain, the nominal liquid pressure can be calculated.

CZPT pumps are self priming. In general it is not required to use an air line lubricator.
The liquid to be pumped flows into the suction chamber by the up-stroke of the generate piston. By this suction impact, the inlet check out valve is opened and the outlet verify valve is closed. The down-stroke generates the strain at the liquid facet. The inlet examine valve is shut and the outlet verify valve is opened by the produced strain. CZPT liquid pumps cycle routinely, exactly where the force is constructed up the quantities of cycles sluggish down, the pump stops immediately when the output force forces are equivalent. The pump restarts with a slight drop in the outlet pressure or an increase in the air drive pressure. Pump functionality can be impacted by a quantity of conditions, this kind of as freezing of muffler or pilot valves (which is triggered by humidity in air traces), inadequate inlet air line dimensions and dirty filers. Never reduce the indicated port sizes and consult CZPT for actual circulation situations not revealed in charts.

Programs incorporate:
 

  1.  Pressure testing
  2.  Burst(Hydrostatic) screening
  3.  Work holding/electrical power clamping
  4.  Jacking/lifting
  5.  Valve actuator control
  6.  CZPT cylinder actuation
  7.  Press basic safety overload devices
  8.  Roller tensioning
  9.  Metering
  10.  CZPT lubrication and spraying
  11.  Liquefied gasoline transfer

Crucial features contain:
 

  1. Compressed Air pushed – no electrical energy required (connect to normal CZPT)
  2. In order to lengthen the lifetime of the pump, the driving air pressure need to

not be greater than eight bar

  1. No airline lubricator necessary
  2. Pressures to 640Mpa (6400 bar) 
  3. Wide assortment of models with various ratios
  4. Constructed-in-cooling on most types
  5. Effortless to put in, operate and keep
  6. Best value / overall performance ratio
  7. No warmth, flame or spark danger and explosion evidence
  8. CZPT strain keeping, whatever the cause of the force drop, the CZPT   pump will immediately start, preserve the loop pressure continual

DGG Series Liquid Pumps(Solitary acting, single air drive head)

  1. DGG pumps have aluminum bodies and wetted resources of stainless steel or carbon metal ,which

  depends on diverse provider liquid. CZPT of stainless metal, make them an superb option
of drinking water software. Higher good quality seals, lengthy services life obtainable.

CZPT specification
 

Design Pressure  Increase Ratio CZPTn air strain PL Method to estimate outlet force MAX Outlet
Stress(bar)*
Liquid inlet Link Liquid outlet Relationship MAX Flow (L/min)
DGG6 6:one two-eight bar 6XPL forty eight NPT1/2 NPT1/two 29.91
DGG10 ten:one 2-8 bar 10XPL 80 NPT1/two NPT1/2 18.84
DGG16 sixteen:1 two-eight bar 16XPL 128 NPT1/2 NPT1/two 12.42
DGG28 28:1 two-eight bar 28XPL 224 NPT1/two NPT1/2 7.eleven
DGG40 40:one 2-8 bar 40XPL 320 NPT1/two NPT1/two four.89
DGG64 sixty four:1 two-eight bar 64XPL 512 NPT1/two NPT3/eight three.08
DGG80 eighty:1 2-eight bar 80XPL 640 NPT1/2 NPT3/eight 2.44
DGG100 a hundred:one 2-8 bar 100XPL 800 NPT1/two NPT3/8 one.92
DGG130 a hundred thirty:1 2-8 bar 130XPL 1040 NPT1/2 M14X1.5 1.47
DGG175 175:1 2-eight bar 175XPL 1400 NPT3/8 M14X1.five one.fourteen
DGG255 255:1 2-8 bar 255XPL 2040 NPT1/four M14X1.5 .seventy five
DGG400 four hundred:one two-eight bar 400XPL 3200 NPT1/4 M14X1.five .forty eight
DGG510 510:one 2-8 bar 510XPL 4080 NPT1/4 M14X1.5 .65
DGG800 800:one 2-eight bar 800XPL 6400 NPT1/four M14X1.five .42

The outlet liquid stress=CZPTn air strain*enhance ratio
In purchase to extend the life time of the pump, the driving air strain should not be greater than 8 bar

DGGD Series Liquid Pumps(Double acting, single air generate head)
They are characterized by the exact same characteristics as the DGG pumps one acting, solitary air drive head kinds,
but they have less pulsations and produce approx. fifty % more circulation.

CZPT specification
 

Product Pressure  Increase Ratio CZPTn air force PL Formulation to estimate outlet stress MAX Outlet
Stress(bar)*
Liquid inlet Link Liquid outlet Relationship MAX Movement (L/min)**
DGGD4 four:one two-eight bar 4XPL 32 NPT1/2 NPT1/two 70.00
DGGD6 6:one 2-eight bar 6XPL 48 NPT1/2 NPT1/2 48.60
DGGD10 ten:one two-8 bar 10XPL eighty NPT1/2 NPT1/two 30.61
DGGD16 16:1 2-8 bar 16XPL 128 NPT1/2 NPT1/two 19.seventy three
DGGD28 28:one two-8 bar 28XPL 224 NPT1/two NPT1/2 11.30
DGGD40 forty:one 2-8 bar 40XPL 320 NPT1/two NPT3/8 seven.69
DGGD64 64:one 2-eight bar 64XPL 512 NPT1/two NPT3/8 four.ninety four
DGGD80 eighty:one two-8 bar 80XPL 640 NPT1/2 NPT3/8 three.96
DGGD100 one hundred:1 2-eight bar 100XPL 800 NPT1/2 NPT3/eight three.13
DGGD130 130:one 2-8 bar 130XPL 1040 NPT1/2 M14*one.5 two.40
DGGD175 175:one 2-eight bar 175XPL 1400 NPT3/eight M14*1.five one.eighty one
DGGD255 255:one two-8 bar 255XPL 2040 NPT1/4 M14*1.5 one.23
DGGD400 four hundred:1 two-8 bar 400XPL 3200 NPT1/4 M14*1.5 .79

The outlet liquid pressure=CZPTn air stress*boost ratio
In order to prolong the lifetime of the pump, the driving air stress ought to not be higher than 8 bar

CZPT DLS Series CZPT (Air pushed) Liquid Booster Method
CZPT- DLS Sequence CZPT(Air driven) CZPT Power Packs
CZPT- CZPT electrical power packs(Liquid pump program) are compact and delicacy solution customized to consumer specific requirements with air pushed liquid pumps as properly as all equipment to be equipped and put in on the frame or in shut cabinet.
To function this system, the pressure gauges, valves and pressure regulators have to be fitted on panels. The outlet pressure is easily to be established by means of a easy air regulator. The pump stops instantly when this end strain is achieved and restarts with a slight fall in the outlet stress or an increase in the air generate strain. CZPT CZPT electrical power packs are accessible with vast variety of stress ratios make these sequence of pumps best for powering a selection of oil/hydraulic operations. The maximum running strain up to 640 MPa.
As the strain will be created by implies of a pneumatically operated pump,the electric relationship will not be needed. To operate this method, the air driven liquid pump have to be geared up with the air handle unit combined filter and water separator, stress-regulating valve, pressure manage gauge as well as manual reduce valve. In this operation, the pump will be mounted to the stainless steel tank in the shut cabinet in a compact and place preserving way. Pressure gauges, valves and force regulators will be equipped on panel.
The preferred operating strain can be attained by modifying the driving air pressure. When the driving air stress and the output force reach the balance, the pump stops filling pressure and the output force stays at the preset value. This hydraulic unit can be utilized for all sorts of strain screening and take a look at tools for analysis and test institutes or for other capabilities necessitating a identified pressure. 

DLS-DGG collection test bench CZPT specification
 

Design Stress Ratio CZPTn air strain PL Method to calculate outlet pressure MAX Outlet
Stress(bar)*
CZPTn
air inlet    port
 
Substantial force Outlet port MAX Movement
(L/min)**
DLS-DGGD4 4:one three-eight bar 4XPL 32 G 1/2 NPT/ZG 70.
DLS-DGG6 six:1 three-eight bar 6XPL forty eight G one/two NPT/ZG 29.ninety one
DLS-DGG10 10:1 three-8 bar 10XPL 80 G 1/two NPT/ZG eighteen.84
DLS-DGG16 sixteen:one three-eight bar 16XPL 128 G one/two NPT/ZG 12.forty two
DLS-DGG28 28:one three-8 bar 28XPL 224 G one/two NPT/ZG 7.eleven
DLS-DGG40 forty:one three-8 bar 40XPL 320 G 1/two NPT/ZG four.89
DLS-DGG64 64:1 3-8 bar 64XPL 512 G 1/2 NPT/ZG 3.08
DLS-DGG80 80:one 3-8 bar 80XPL 640 G one/2 NPT/ZG 2.forty four
DLS-DGG100 one hundred:one 3-eight bar 100XPL 800 G 1/2 NPT/ZG 1.92
DLS-DGG130 130:1 3-eight bar 130XPL 1040 G one/2 NPT/ZG one.forty seven
DLS-DGG175 175:1 three-8 bar 175XPL 1400 G one/two NPT/ZG one.fourteen
DLS-DGG255 255:1 3-8 bar 255XPL 2040 G one/2 NPT/ZG .75
DLS-DGG400 400:1 three-8 bar 400XPL 3200 G one/two NPT/ZG .48
DLS-DGG510 510:one three-eight bar 510XPL 4080 G 1/two NPT/ZG .sixty five
DLS-DGG800 800:1 3-eight bar 800XPL 6400 G one/2 NPT/ZG .42

DLS-M sequence check bench CZPT specification
 

Model Strain  Boost Ratio CZPTn air pressure PL Method to calculate outlet pressure MAX Outlet
Force(bar)*
CZPTn
air inlet    port
 
High force outlet port MaxFlow rate(L/min)**
DLS-DGM4 4:one 3-8 bar 4XPL 32 G one/two NPT/ZG fifteen.36
DLS-DGM100 10:1 3-eight bar 10XPL eighty G 1/two NPT/ZG 7.15
DLS-DGM16 16:one 3-8 bar 16XPL 128 G one/two NPT/ZG 4.59
DLS-DGM30 30:one 3-eight bar 30XPL 240 G one/2 NPT/ZG two.fifty three
DLS-DGM44 44:one 3-eight bar 44XPL 352 G one/two NPT/ZG 1.41
DLS-DGM64 sixty four:one three-8 bar 64XPL 512 G one/two NPT/ZG .95
DLS-DGM100 100:one three-eight bar 100XPL 800 G 1/2 NPT/ZG .sixty four
DLS-DGM170 170:1 3-8 bar 170XPL 1360 G one/2 NPT/ZG .37

CZPT Co., Ltd is the member company of CZPT Team, which is situated in HangZhou metropolis of ZheJiang province in China. With far more than 15 several years ordeals in fluid pressure trade and managing discipline, we offer various kinds of pneumatic and hydraulic booster pumps, techniques and answers to the buyers all above the world. Owing to our ideal merchandise high quality, competitive price as effectively as outstanding after-revenue service, we have earn a great track record in the area.
 
Our principal products which includes:
High Force Booster Pumps (Air CZPTn Gas Booster Pump, Air CZPTn Liquid Pump, Air Amplifiers)
High Pressure Methods (Gas/Liquid Booster Stations,FM200 filling device, Tube Increasing CZPT)
High Strain Take a look at CZPT(CZPT/Burst/Hydrostatic examination equipment,Cylinder test device,
Valve take a look at bench,Impulse Testing CZPT, etc.)
 
Product Software
Oil CZPT, Gasoline CZPT, CZPT CZPT, Fire Combating, Study Establishments and many others.
 
Our services
13 months’ free guarantee given that the getting date and cost-free complex help during life span

 

Suncenter Brand Model: Dggd10 10: 1 Ratio Air Driven High Pressure Liquid Pump for Pressure Gauge Testing

Leave a Reply

Your email address will not be published. Required fields are marked *